Testing for Harmful Substances in Food: SMART

The SMART Series: A Game-Changer in Testing Paradigms

It reduces testing time by more than 90% compared to conventional microbiological testing methods (which take 4–5 days) 

and can simultaneously detect up to 78 types of residual harmful substances using a single cassette. 

This immunochromatography rapid test kit has become the industry standard in Korea’s dairy, livestock, fisheries, and egg sectors.

Results in 10 minutes icon
10 min
Results within 10 minutes
Simultaneous detection of up to 78 types icon
Up to 78 types
Simultaneous detection
AOAC certified icon
AOAC Certified
Internationally recognized accuracy

SMART's 3 Key Competitive Advantages

Diversity
Simultaneous Detection of Multiple Antibiotics
Up to 6 groups with a single cassette
Detects 78 types (the most in the world)
Speed
See results in 10 minutes or less

Compared to existing microbial culture methods,

test time is reduced by approximately 90% or more

Reliability
Internationally Certified Accuracy
Combo 1 has completed AOAC certification; Combo 2, 3, and 4 are currently undergoing certification.

Applicable Food Groups 

It consists of four product lines optimized for 

the characteristics of each food group. 

You can find the product codes, detectable

antibiotics, and usage instructions on 

each product line’s detail page.

Milk
SMART kit - Milk
Dairy farms, dairy processing companies
(Seoul Milk, Maeil Dairy, etc.)View more +
Meat
SMART kit - Meat
Slaughterhouses, Meat Processing Plants
(Beef, Pork, Chicken)

View more +

Seafood
SMART kit - Fish
Fish Farms, Seafood Processing Companies
(Fish and Shellfish)

         View more +

Egg
SMART kit - Egg
Laying hen farms,
Egg distribution and processing companies

View more +

Frequently Asked Questions 

FAQ

Q

Why is residue testing necessary?

A

Veterinary drugs such as antibiotics used to treat livestock can remain in milk, meat, eggs and seafood if withdrawal periods are not observed or the drugs are misused. Because residues raise concerns such as allergic reactions and the spread of antibiotic-resistant bacteria, maximum residue limits (MRLs) are set and enforced by law.

In Korea, the Positive List System (PLS) for veterinary drugs has applied to livestock and fishery products since January 2024. Any substance without an established MRL is held to a uniform limit of 0.01 mg/kg or less. Products that exceed the limits cannot be shipped or sold, so testing at the production and processing stages is essential to keep non-compliant products off the market.

Q

What are the advantages of rapid test kits over other residue testing methods?

A

Residue testing methods fall into three main types: microbial inhibition tests, instrumental analysis, and rapid test kits. Rapid test kits deliver results on site within 10 minutes and report results by drug class, making it easier to trace the source drug.

MethodPrincipleResultsCharacteristics
Microbial inhibition testChecks whether antimicrobial substances inhibit bacterial growthAfter incubationCovers a broad range of antibiotics; difficult to identify the drug class
Instrumental analysis (LC-MS/MS, etc.)Separates substances to measure type and concentrationLaboratory analysisPrecise quantification; requires a specialized lab and costly equipment
Rapid test kit (SMART)Immunochromatography using antibodies that bind specific substancesOn site, within 10 minResults by drug class; low equipment burden and cost per test, suited to full screening

With low equipment requirements and a low cost per test, rapid kits are well suited to screening every tanker or every shipment lot.

Q

Which substances can Celltrix rapid test kits detect?

A

Celltrix supplies test kits built on its own in-house developed antibodies, focusing mainly on antibiotic classes. A single cassette can detect up to 6 groups at once.

Four product lines are available by food type: Milk, Meat, Seafood and Egg. Detection items and detection limits for each product are listed on the product line pages and in the product instructions.

Q

What should I do if a rapid test kit shows a positive result?

A

A rapid test kit is a screening test that quickly identifies samples that may exceed the limits. When a result is positive, the standard procedure is to hold the raw milk or product from blending and shipment, and confirm the substance and concentration through instrumental analysis at an accredited laboratory.

In practice, screening the entire volume with rapid kits and sending only positive samples for confirmatory testing is the most efficient approach in terms of both speed and cost.

Q

Where is residue testing mainly used?

A

The most common application is incoming raw milk testing at milk collection centers. Because milk from many farms is pooled in a single tanker, residues from one farm can render the entire tanker non-compliant, making testing before intake essential. Celltrix SMART rapid test kits are supplied to approximately 90% or more of milk collection centers in Korea.

Residue testing is also used at slaughterhouses and meat processing plants, in egg and seafood production and distribution, and by farms checking that the withdrawal period has passed before shipping animals after treatment.

Regulatory Trends 

Why SMART?

• Expansion of the Domestic PLS (Positive List System): Agricultural Products (2019) → Livestock, Aquatic Products, and Seafood (2024) → Amphibians and Insects (2026)


• Trend Toward Tighter Global Regulations, Including the EU’s “Zero-Tolerance Policy” and Strengthened FDA Measures


• “Organic and Antibiotic-Free Livestock and Seafood Certification” and HACCP-Certified Farms Expanded to 850


• The Ministry of Food and Drug Safety is currently developing and standardizing testing methods for 31 prohibited substances—with the goal of having the SMART kit listed as a standard testing method

celltrix Co., Ltd.

HQ: 124 Sagimakgol-ro, SKn Technopark Biz 1014, Jungwon-gu, Seongnam-si, Gyeonggi-do, South Korea

KVL : 700 Daewangpangyo-ro, Korea Bio Park B-501, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea

Phone: +82-31-776-3538  l  Fax: +82- 31-776-0262  l  E-mail: info@celltrix.com

Copyright © celltrix All rights reserved.