Molecular Diagnostics / Rapid PCR (LAMP) 

Livestock Disease Genetic Testing, 

Read by Color Change Instead of Instruments 

Qtest® LAMP kits amplify target genes at a single temperature 

and show the result as a color change in the reaction solution. 

Celltrix holds product approvals from Korea's Animal and Plant Quarantine Agency (APQA)

for its genetic test kits for avian influenza (AI), foot-and-mouth disease (FMD), 

and African swine fever (ASF), as well as its nucleic acid extraction kit. 

Fast results
in just 1 hour
Rapid on-site diagnosis
Product approval completed

Rapid PCR (LAMP)

Rapid PCR product list

Item Name (Class)
Product Name
Detection Target 
Zoonotic Disease Genetic Test Reagent
(Class 3)
Qtest AIV M Rapid PCR Kit
Avian influenza virus type A (M gene)
High-Risk Animal Infectious Disease Genetic Test  Reagent 
(Class 3)
Qtest FMDV pan Rapid PCR kit
FMD (Foot-and-mouth) disease virus, 7 serotypes (O, A, Asia1, C, SAT1, SAT2, SAT3)
High-Risk Animal Infectious Disease Genetic Test Reagent 
(Class 3)
Qtest ASFV Rapid PCR kit
ASFV African swine fever virus (Genotype II) 
Nucleic Acid Extraction Reagent
(Class 1)
Qtest Prep Kit Syringe Filter 
Nucleic acids (DNA, RNA) from animal-derived specimens 

LAMP: Gene Amplification at a Single Temperature 

Real-time PCR requires repeated thermal cycling, raising and lowering the temperature dozens of times, as well as dedicated instruments to read fluorescence.
LAMP (Loop-mediated Isothermal Amplification) uses multiple specific primers that bind to the target gene,
amplifying it at a single temperature of 58–63โ„ƒ.
Qtest Rapid PCR kits contain a color indicator in the reaction mix,
 allowing positive and negative results to be distinguished by eye, without electrophoresis or real-time PCR instruments. 

Item
Qtest® LAMP
Real-time PCR (general)
Amplification
Isothermal reaction at a single temperature (58–63โ„ƒ)
Thermal cycling through denaturation, annealing, and extension
Reaction time
30–40 min (plus 2–5 min termination)
Varies by instrument and protocol
Equipment
Constant-temperature device
(heating block, thermal cycler, etc.)
Real-time PCR instrument with fluorescence detection
Readout
Visual reading of reaction color
Amplification curve and Ct value analysis
Testing setting
Laboratories without high-cost instruments and field testing sites
Fully equipped diagnostic laboratory

From Sample to Result

Every step, from nucleic acid extraction to result reading, can be performed without a centrifuge, automated extraction system, or real-time PCR instrument.  

  1. Sample Collection

    Collect the specimen specified for each disease, such as feces, blood, tissue, or vesicular fluid.

  2. Nucleic Acid Extraction

    Mix the sample with Lysis Buffer from the Prep Kit, heat it, and filter it through a syringe filter.

    95โ€“100โ„ƒ, 5โ€“10 min
  3. Isothermal Amplification

    Add the extracted nucleic acid to the reaction tube and incubate at a constant temperature.

    58โ€“63โ„ƒ, 30โ€“40 min
  4. Color Readout

    Read the result by eye right after the reaction. Blue is positive, and purple is negative.

Positive

Blue

The target gene has been amplified, turning the reaction solution blue.

Negative

Purple

No amplification has occurred, so the reaction solution remains its original purple.

Color Chart

Positive Retest Negative

The more target gene present, the more vivid the blue. Colors between blue and purple require retesting. This chart is based on the Qtestยฎ AIV M Rapid PCR Kit instructions for use, and actual colors may vary depending on the environment, equipment, specimen condition, and display.

  • Read the result immediately after the reaction, with the tube cap kept closed.
  • Turbidity of the reaction solution may vary with specimen type, so judge the result by color, not turbidity.
  • If the color does not clearly indicate positive or negative, retest the sample or perform an additional diagnostic test such as real-time PCR.

Frequently Asked Questions 

FAQ

Q

Which foot-and-mouth disease (FMD) test kit do you offer?

A

Celltrixโ€™s FMD genetic test kit is the Qtest FMDV pan Rapid PCR kit (APQA Product Approval No. 250-031). Using nucleic acid extracted from vesicular fluid, vesicular epithelium, blood, saliva, and other specimens, it detects all seven serotypes of foot-and-mouth disease virus (FMDV): O, A, Asia1, C, SAT1, SAT2, and SAT3.

Results are read by the color of the reaction solution after a 40-minute reaction at 62โ„ƒ. In the performance tests for product approval, results were concordant for all 60 positive and 100 negative specimens.

Q

What is your African swine fever (ASF) test kit?

A

The Qtest ASFV Rapid PCR kit (APQA Product Approval No. 250-032) detects the genes of African swine fever virus (ASFV) Genotype II in pig blood or tissue. The reaction takes 30 minutes at 63โ„ƒ.

In the approval performance tests on 159 samples (50 positive, 109 negative), results agreed 100% with confirmed diagnoses (Cohenโ€™s Kappa 1.00). No cross-reactivity was observed with major swine pathogens, including classical swine fever (CSF) virus, PRRSV, and porcine circovirus.

Q

Do you also offer an avian influenza (AI, bird flu) test kit?

A

The Qtest AIV M Rapid PCR Kit (APQA Product Approval No. 250-030) detects the M gene of avian influenza virus (AIV) type A in feces from chickens, ducks, and wild birds by reverse transcription LAMP (RT-LAMP).

In the approval performance tests, it detected all 96 virus strains across 50 subtypes from H1 to H14, and agreed 100% with standard rRT-PCR on 128 AIV surveillance samples. Because the test identifies type A virus, additional diagnostic testing is required to determine subtypes such as H5 and H7.

Q

How is LAMP different from conventional PCR?

A

Real-time PCR requires repeated thermal cycling and fluorescence detection equipment. LAMP (Loop-mediated Isothermal Amplification) amplifies genes at a single temperature of 58โ€“63โ„ƒ, and Qtest kits show the result as a color change in the reaction solution: blue for positive, purple for negative.

MethodAmplificationEquipmentReadout
Real-time PCR (general)Repeated thermal cyclingReal-time PCR instrumentAmplification curve, Ct value analysis
Qtest LAMP kitIsothermal reaction at a single temperature (58โ€“63โ„ƒ)Isothermal device such as a heating blockVisual reading of reaction color

Although the product names include โ€œRapid PCR Kit,โ€ the amplification principle is LAMP.

Q

Can the kits be used at field testing sites outside the laboratory?

A

Because no high-cost real-time PCR instrument is needed, the kits can be used at laboratories with limited equipment and at field testing sites for disease control. With the Mmisoยฎ Prep Kit Syringe Filter (APQA Product Approval No. 250-033), nucleic acid extraction requires only heating and syringe filtration, with no centrifuge, and the kit is stored at room temperature (1โ€“30โ„ƒ).

However, these products are for professional use by official veterinary diagnostic institutions, such as provincial and national animal disease control agencies, and cannot be used directly by livestock farmers.

celltrix Co., Ltd.

HQ: 124 Sagimakgol-ro, SKn Technopark Biz 1014, Jungwon-gu, Seongnam-si, Gyeonggi-do, South Korea

KVL : 700 Daewangpangyo-ro, Korea Bio Park B-501, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea

Phone: +82-31-776-3538  l  Fax: +82- 31-776-0262  l  E-mail: info@celltrix.com

Copyright © celltrix All rights reserved.

Designed by VisualLab